When a window is approved for the High-Velocity Hurricane Zone, it has passed one of the toughest test batteries in the building world. The HVHZ protocols, TAS 201, 202 and 203, simulate what a hurricane actually does to an opening: airborne debris, then hours of violent pressure swings.
TAS 201: large-missile impact
The headline test. A nine-pound piece of lumber, essentially a two-by-four, is fired from a cannon at the glass at around 50 feet per second. It has to strike the panel and a corner. The interlayer may crack, but the opening must not be breached. This is the moment that separates impact glass from ordinary glazing.
Small-missile impact
For openings higher up on a building, a burst of small steel balls stands in for roof gravel and smaller debris carried at higher speed. The requirement is the same: no penetration.
TAS 202: uniform static pressure
The window is loaded with steady positive and negative pressure to confirm its structural design pressure, the number you later see on the Florida Product Approval. This proves the frame, glass and anchors hold under the peak load.
TAS 203: cyclic wind pressure
This is the endurance test. After being struck, the already-damaged window is put through thousands of pressure cycles, positive and negative, mimicking the hours a storm spends pushing and pulling on a wall. The opening still has to keep the weather out.
Passing means a window that has been hit by a flying two-by-four still holds through thousands of pressure cycles without letting the storm in.
Every HVHZ line on a Florida Product Approval traces back to this sequence, run on a specific configuration at a specific size and pressure. Where a VALDA approval covers the HVHZ, it lists each configuration, size and design pressure it was tested to.
FAQ
Frequently asked
What is the large-missile impact test?
It is the TAS 201 protocol, in which a roughly nine-pound two-by-four is fired at the window at about 50 feet per second. The window must not be breached, which is what qualifies it as impact rated for the hurricane zone.
What do TAS 201, 202 and 203 mean?
They are the test protocols for the High Velocity Hurricane Zone (HVHZ): TAS 201 is large-missile impact, TAS 202 is uniform static pressure, and TAS 203 is cyclic wind pressure. A hurricane-zone window must pass all three.
Does the glass break during the impact test?
The outer glass can crack. What matters is that the laminated interlayer keeps the opening sealed so wind and debris cannot get through, then survives the cyclic pressure that follows.
Planning a project?
Tell us about your openings and we will match the right certified system.